Users Manual Part 3
Table Of Contents
- 3. System Fails Post-Installation Checks
- 4. Incorrect Navigation Data
- 5. System Will Not Connect to the Network
- 6. Connectivity of Each Ethernet Port
- SECTION 7 – MAINTENANCE AND REPAIR
- 1. Maintenance Requirements
- 2. Continued Airworthiness, FAR 25.1529
- 3. Airworthiness Limitations
- 4. General Instructions for Inspection
- 5. Electrical and Mechanical Inspection and Check
- 6. Instructions for Continued Airworthiness
- 7. Visual Inspection and Check
- 8. Scheduled Maintenance and Inspections
- 9. Unscheduled Maintenance
- 10. Repair Requirements
- APPENDIX A – ENVIRONMENTAL CHARACTERISTICS
- APPENDIX B – INFORMATION SHEETS
- 1. Aircraft Information Sheet
- 2. JetWave™ MCS-8562 Terminal AES Subsystem Components
- A. JetWave™ MCS-8562 Terminal AES OAE - FMA Installation Information Sheet
- B. JetWave™ MCS-8562 Terminal AES KANDU Installation Information Sheet
- C. JetWave™ MCS-8562 Terminal AES BUC-HPA Installation Information Sheet
- D. JetWave™ MCS-8562 Terminal AES Modman Installation Information Sheet
- E. JetWave™ MCS-8562 Terminal AES APM Installation Information Sheet
- APPENDIX C – CHECKLISTS
- APPENDIX D – CUSTOMER PORTAL
- 1. Customer Portal
- 2. APM Request Form
- A. Requester Name
- B. Requester Email
- C. Honeywell Representative Name
- D. Hon Representative Email
- E. PO Number
- F. DP/VAR/Customer Name
- G. DP/VAR/Customer Name Contact Name
- H. DP/VAR/Customer Name Contact Email
- I. Channel Partner/Integrator/STC
- J. Estimated APM Due Date
- K. Aircraft Make / Aircraft Model
- L. Aircraft Model Variant
- M. Additional Notes/Comments
- 3. APM Parameter File
- 4. Request Assistance
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Reboot the system, if
problem persists,
replace Modman
Critical Faults
RSSI +1V3
POWER GOOD
-POWER FAIL
35
Controller/
Router
2ModMan1
could happen as part
of normal shut down
Status
Message
PSU INPUT
POWER FAIL
1
Power
Supply Unit
3ModMan1
could happen as part
of normal shut down
Status
Message
PSU GOOD
POWER FAIL
2
Power
Supply Unit
3ModMan1
could happen as part
of normal shut down
Status
Message
ACM 18V
POWER GOOD
1Backplane4ModMan1
Status
Message
successful login3
AES SFTP/
SSH
E0ModMan1
Status
Message
failed login4
AES SFTP/
SSH
E0ModMan1
Status
Message
successful login3AES GUIE1ModMan1
Status
Message
failed login4AES GUIE1ModMan1
Status
Message
successful login3
LRU SFTP/
SSH
E2ModMan1
Status
Message
failed login4
LRU SFTP/
SSH
E2ModMan1
Status
Message
successful login3
SNMP
Engineering
E3ModMan1
Status
Message
failed login4
SNMP
Engineering
E3ModMan1
Status
Message
successful login3
SNMP
ARINC 791
E4ModMan1
Status
Message
failed login4
SNMP
ARINC 791
E4ModMan1
Status
Message
Mode Transition0
Operational
Information
FAModMan1
Status
Message
Parameter1
Operational
Information
FAModMan1
Status
Message
Operational
Event
2
Operational
Information
FAModMan1
Status
Message
Connect Event4
Operational
Information
FAModMan1
Page 6-20
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal