Users Manual Part 3

Table Of Contents
CategoryConditionSection
BHumidity6
NOTE: At least six spot checks are required.
B and EOperational shocks and crash safety7
CAT S, CURVE C
CAT R, CURVE C1
Vibration8
NOTE: The sinusoidal sweep rate not to exceed 0.5 octaves/minute
EExplosive atmosphere9
Y and WWaterproofness10
FFluid susceptibility - De-ice fluids only11
D and SSand and dust12
FFungus resistance13
SSalt fog14
BMagnetic effect15
X - not requiredPower input16
X - not requiredVoltage spike17
X - not requiredAudio frequency conducted susceptibility18
ZCInduced signal susceptibility19
YQRadio frequency susceptibility20
NOTE: Q (custom) only - SW/CW (un-modulated) signal Operational:
200V/m for 100 MHz to 12 GHz
0.1 V/m 12 GHz to 16.6 GHz
No damage:
200V/m for 12 GHz to 16.6 GHz
0.1 V/m for 16.6 GHz to 18 GHz
Cat H Modified.Emissions of RF energy21
NOTE:
Extension of conducted emissions limits to 200 MHz at 3 dBµA.
Extension of radiated emissions to start at 45 dBµV/m at 150 kHz continuing linearly to 40dBuV/
m at 2MHz, then continuing linearly to 36.3dBuV/m at 30MHz then continuing linearly to 44.5
dBµV/m at 100 MHz. The standard category H curve to follow beginning at 100 MHz.
A3K3L3Lightning induced transient susceptibility22
NOTE: Pin Injection waveform 5A level 125V/125A and 400V/4A. Single stroke WF 4, level 3
(extended to 300V/1000A), Multi-stroke WF4 level 3 (extended to 120V/400A 1st stroke, 75V/
150A subsequent strokes).
X - not requiredLightning direct effects23
BIcing24
Page A-6
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal