Users Manual Part 3

Table Of Contents
CategoryConditionSection
QEmissions of RF energy21
NOTE:
Extension of conducted emissions limits to 200 MHz at 20 dBµA and power line limits from 30
MHz to 108 MHz at 20 dBµA.
Extension of radiated emissions to start at 45 dBµV/m at 150 kHz to 40 dBµV/m at 2 MHz, and
at 30 dBµV/m at 2 MHz to 25 dBµV/m at 25 MHz, and at 25 dBµV/m at 25 MHz to 26.3 dBµV/m
at 30 MHz, and at 36.3 dBµV/m at 30 MHz to 44.5 dBµV/m at 100 MHz.
All conducted emissions limits, including interconnecting bundles limits, are set in accordance
with Category Q power line limit levels.
A3K3L3Lightning induced transient susceptibility22
NOTE: Extended to include pin injection waveform 5A level 2.
X - not requiredLightning direct effects23
AIcing24
AElectrostatic discharge25
C - covers 14 CFR 25.853Fire, flammability26
D. BUC-HPA
CategoryConditionSection
D2Temperature and altitude4
Z (30 minutes)Loss of cooling
NOTE: Altitude test extended to 55,000 feet (16764m). Overpressure 28.9 PSI (199 kPa),
Decompression 6,000 to 55,000 (1,828.8 to 16,764.0 m).
ATemperature variation5
BHumidity6
NOTE: At least six spot checks required.
E and BOperational shocks and crash safety7
CAT R, CURVE E
CAT R, CURVE E1
Vibration8
NOTE: The sinusoidal sweep rate not to exceed 0.5 octaves/minute.
EExplosive atmosphere9
Y and RWaterproofness10
FFluid susceptibility11
NOTE: Ethylene Glycol, Propylene Glycol, AEA Type 1, AEA Type 2.
DSand and dust12
FFungus resistance13
SSalt fog14
ZMagnetic effect15
Page A-4
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal