Users Manual Part 3
Table Of Contents
- 3. System Fails Post-Installation Checks
- 4. Incorrect Navigation Data
- 5. System Will Not Connect to the Network
- 6. Connectivity of Each Ethernet Port
- SECTION 7 – MAINTENANCE AND REPAIR
- 1. Maintenance Requirements
- 2. Continued Airworthiness, FAR 25.1529
- 3. Airworthiness Limitations
- 4. General Instructions for Inspection
- 5. Electrical and Mechanical Inspection and Check
- 6. Instructions for Continued Airworthiness
- 7. Visual Inspection and Check
- 8. Scheduled Maintenance and Inspections
- 9. Unscheduled Maintenance
- 10. Repair Requirements
- APPENDIX A – ENVIRONMENTAL CHARACTERISTICS
- APPENDIX B – INFORMATION SHEETS
- 1. Aircraft Information Sheet
- 2. JetWave™ MCS-8562 Terminal AES Subsystem Components
- A. JetWave™ MCS-8562 Terminal AES OAE - FMA Installation Information Sheet
- B. JetWave™ MCS-8562 Terminal AES KANDU Installation Information Sheet
- C. JetWave™ MCS-8562 Terminal AES BUC-HPA Installation Information Sheet
- D. JetWave™ MCS-8562 Terminal AES Modman Installation Information Sheet
- E. JetWave™ MCS-8562 Terminal AES APM Installation Information Sheet
- APPENDIX C – CHECKLISTS
- APPENDIX D – CUSTOMER PORTAL
- 1. Customer Portal
- 2. APM Request Form
- A. Requester Name
- B. Requester Email
- C. Honeywell Representative Name
- D. Hon Representative Email
- E. PO Number
- F. DP/VAR/Customer Name
- G. DP/VAR/Customer Name Contact Name
- H. DP/VAR/Customer Name Contact Email
- I. Channel Partner/Integrator/STC
- J. Estimated APM Due Date
- K. Aircraft Make / Aircraft Model
- L. Aircraft Model Variant
- M. Additional Notes/Comments
- 3. APM Parameter File
- 4. Request Assistance
B. JetWave™ MCS-8562 Terminal AES system status can be viewed through the GUI. Refer to
Checking Status Information section for description.
C. On the Modman LRU the status indicator LED is on the Modman front panel. The various Modman
status indications are shown in Table 7-3.
Table 7-3. Modman LED Status Indications
ModeStatus LED
No electrical power/electrical power is supplied but prior
to boot.
Off
Modman initializationFlash green at a minimum of 10 seconds
Modman in normal operationOn - green
Modman in Fault ModeOn - red
10. Repair Requirements
A. The BITE functionality of JetWave™ MCS-8562 Terminal AES system can identify the faulty LRU
in the case of any occurrence of functional problems and this can be accessed through Modman.
B. In accordance with continued airworthiness instructions, if a JetWave™ MCS-8562 Terminal AES
system is inoperative, use Standard Practices Chapter of the Aircraft Maintenance Manual to:
Remove the unit-
- Secure cables and wiring
- Collar applicable switches and circuit breakers, and placard them as “inoperative”.
Before flight, revise the equipment list and weight and balance data as applicable, and record the
removal of the unit in the log book. Refer to section 91.213 of the FAR or the aircraft’s minimum
equipment list. All repairs must be done at the Honeywell factory.