Users Manual Part 3

Table Of Contents
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 data load
- Data Load IP Modman
- Data Load IP KANDU
- Data Load IP OAE
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services config Modman
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services config KANDU
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services config OAE
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services IP Modman
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services IP KANDU
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services IP OAE
- User Port AES services IP subnet
- User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 traffic services
- User Port IP filter 1 thru 150.
Once the items have been loaded into the APM the Modman reads the APM once at power-on and passes
the appropriate data to the relevant LRU or uses the information locally.
A. If the Ethernet port is not active, do as follows:
(1) Check the APM settings, as follows:
(a) Make sure that the port is enabled.
(b) Check system errors.
(c) Check for system reporting No layer 1 or No traffic faults.
(2) Is the device connecting to it operating correctly? If so, check the wiring.
(3) Make sure that the system in the correct mode.
B. It there is poor performance on one port only, do as follows:
(1) Check for port reporting high packet loss. If so, check wiring and verify that there is traffic.
C. If not supplying access to the correct services, do as follows:
(1) Make sure the APM is configured for the correct services.
(2) Make sure the APM is configured to access the correct VLANs.
Check with the service provider to make sure that the VLANs have been correctly configured
for the terminal.
Page 6-83
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal