Users Manual Part 3
Table Of Contents
- 3. System Fails Post-Installation Checks
- 4. Incorrect Navigation Data
- 5. System Will Not Connect to the Network
- 6. Connectivity of Each Ethernet Port
- SECTION 7 – MAINTENANCE AND REPAIR
- 1. Maintenance Requirements
- 2. Continued Airworthiness, FAR 25.1529
- 3. Airworthiness Limitations
- 4. General Instructions for Inspection
- 5. Electrical and Mechanical Inspection and Check
- 6. Instructions for Continued Airworthiness
- 7. Visual Inspection and Check
- 8. Scheduled Maintenance and Inspections
- 9. Unscheduled Maintenance
- 10. Repair Requirements
- APPENDIX A – ENVIRONMENTAL CHARACTERISTICS
- APPENDIX B – INFORMATION SHEETS
- 1. Aircraft Information Sheet
- 2. JetWave™ MCS-8562 Terminal AES Subsystem Components
- A. JetWave™ MCS-8562 Terminal AES OAE - FMA Installation Information Sheet
- B. JetWave™ MCS-8562 Terminal AES KANDU Installation Information Sheet
- C. JetWave™ MCS-8562 Terminal AES BUC-HPA Installation Information Sheet
- D. JetWave™ MCS-8562 Terminal AES Modman Installation Information Sheet
- E. JetWave™ MCS-8562 Terminal AES APM Installation Information Sheet
- APPENDIX C – CHECKLISTS
- APPENDIX D – CUSTOMER PORTAL
- 1. Customer Portal
- 2. APM Request Form
- A. Requester Name
- B. Requester Email
- C. Honeywell Representative Name
- D. Hon Representative Email
- E. PO Number
- F. DP/VAR/Customer Name
- G. DP/VAR/Customer Name Contact Name
- H. DP/VAR/Customer Name Contact Email
- I. Channel Partner/Integrator/STC
- J. Estimated APM Due Date
- K. Aircraft Make / Aircraft Model
- L. Aircraft Model Variant
- M. Additional Notes/Comments
- 3. APM Parameter File
- 4. Request Assistance
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Status
Message
FAILED4
MISSION
CONFIG
FILE
PURGE
DCSystem0
Status
Message
SUCCESSFUL3
MISSION
CONFIG
FILE
CREATED
FROM GUI
DDSystem0
Status
Message
FAILED4
MISSION
CONFIG
FILE
CREATED
FROM GUI
DDSystem0
Status
Message
Mute State0Unknown0ModMan1
Status
Message
Log clearance
LRU
Operational
21Unknown0ModMan1
Status
Message
Log clearance
LRU Fault
22Unknown0ModMan1
Status
Message
ACM NOT
RESPONDING
1ACM1ModMan1
Status
Message
ACM BIST
FAULT
2ACM1ModMan1
Status
Message
ACM OVER
TEMP
3ACM1ModMan1
Status
Message
ACM POST
Failure
8ACM1ModMan1
Status
Message
ACM NO
RESPONSE
4ACM1ModMan1
Reboot the system, if
problem persists,
replace Modman
Critical FaultsDSP Fault1
Controller/
Router
2ModMan1
Reboot the system, if
problem persists,
replace Modman
Critical Faults
Ethernet Main
Switch
2
Controller/
Router
2ModMan1
Reboot the system, if
problem persists,
replace Modman
Critical Faults
Ethernet PODD
Switch
3
Controller/
Router
2ModMan1
Page 6-16
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal