Users Manual Part 3
Table Of Contents
- 3. System Fails Post-Installation Checks
- 4. Incorrect Navigation Data
- 5. System Will Not Connect to the Network
- 6. Connectivity of Each Ethernet Port
- SECTION 7 – MAINTENANCE AND REPAIR
- 1. Maintenance Requirements
- 2. Continued Airworthiness, FAR 25.1529
- 3. Airworthiness Limitations
- 4. General Instructions for Inspection
- 5. Electrical and Mechanical Inspection and Check
- 6. Instructions for Continued Airworthiness
- 7. Visual Inspection and Check
- 8. Scheduled Maintenance and Inspections
- 9. Unscheduled Maintenance
- 10. Repair Requirements
- APPENDIX A – ENVIRONMENTAL CHARACTERISTICS
- APPENDIX B – INFORMATION SHEETS
- 1. Aircraft Information Sheet
- 2. JetWave™ MCS-8562 Terminal AES Subsystem Components
- A. JetWave™ MCS-8562 Terminal AES OAE - FMA Installation Information Sheet
- B. JetWave™ MCS-8562 Terminal AES KANDU Installation Information Sheet
- C. JetWave™ MCS-8562 Terminal AES BUC-HPA Installation Information Sheet
- D. JetWave™ MCS-8562 Terminal AES Modman Installation Information Sheet
- E. JetWave™ MCS-8562 Terminal AES APM Installation Information Sheet
- APPENDIX C – CHECKLISTS
- APPENDIX D – CUSTOMER PORTAL
- 1. Customer Portal
- 2. APM Request Form
- A. Requester Name
- B. Requester Email
- C. Honeywell Representative Name
- D. Hon Representative Email
- E. PO Number
- F. DP/VAR/Customer Name
- G. DP/VAR/Customer Name Contact Name
- H. DP/VAR/Customer Name Contact Email
- I. Channel Partner/Integrator/STC
- J. Estimated APM Due Date
- K. Aircraft Make / Aircraft Model
- L. Aircraft Model Variant
- M. Additional Notes/Comments
- 3. APM Parameter File
- 4. Request Assistance
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Check connection
from KANDU to OAE
Critical Faults
Ethernet High
packet loss
2
KANDU
Input
1
KANDU
OAE
Ethernet
Bus
30
Status
Message
Ethernet
Normal
3
KANDU
Input
1
KANDU
OAE
Ethernet
Bus
30
Check connection
from OAE to KANDU
Critical Faults
Ethernet No
Layer 1
0OAE Input2
KANDU
OAE
Ethernet
Bus
30
Check connection
from OAE to KANDU
Critical Faults
Ethernet No
traffic
1OAE Input2
KANDU
OAE
Ethernet
Bus
30
Check connection
from OAE to KANDU
Critical Faults
Ethernet High
packet loss
2OAE Input2
KANDU
OAE
Ethernet
Bus
30
Status
Message
Ethernet
Normal
3OAE Input2
KANDU
OAE
Ethernet
Bus
30
Check connection
from KANDU to OAE
Critical FaultsSerial Inactive1
KANDU
Input
1
KANDU
OAE Serial
Control
Bus
31
Check connection
from KANDU to OAE
Critical Faults
Serial High
packet loss
2
KANDU
Input
1
KANDU
OAE Serial
Control
Bus
31
Status
Message
Serial Normal3
KANDU
Input
1
KANDU
OAE Serial
Control
Bus
31
Check connection
from OAE to KANDU
Critical FaultsSerial Inactive1OAE Input2
KANDU
OAE Serial
Control
Bus
31
Page 6-50
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal