Users Manual Part 3

Table Of Contents
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Status
Message
Secondary
Image
Corruption
Warning
B
Software
Configuration
FDKANDU6
Status
Message
OTA Staged
Software
DataLoad
C
Software
Configuration
FDKANDU6
Check LRU serial
connection
Status
Message
Heartbeat
failure
0
Software
Runtime
FEKANDU6
Reboot the unit, if
persist, replace the
KANDU
Critical Faults
GENERAL
Module failure
1
software
runtime
FEKANDU6
Use SB6 EUI tool to fix
Critical Faults
FILE SYSTEM
FULL
20
Software
Runtime
FEKANDU6
Note: this can be a
false positive
Status
Message
RSSI Failure2
Software
Runtime
FEKANDU6
If this fault does not
clear, Check Modman
KADNU and the
connection inbetween
Status
Message
OPENAmip
failure
3
Software
Runtime
FEKANDU6
Reboot the system, if
cannot complete
POST, replace the unit
Status
Message
Pointing failure4
Software
Runtime
FEKANDU6
Status
Message
LRU mtd
partition
unlocked
5
Software
Runtime
FEKANDU6
check the Part number
of BUC and WBFMA.
Also check that
mission config
parameters are correct
warning
TX and/or RX
LO Config
Mismatch: SP
_WB_FMA1
31
Software
Runtime
FEKANDU6
check the Part number
of BUC and WBFMA.
Also check that
mission config
parameters are correct
warning
TX and/or RX
polarity
Mismatch: SP
_WB_FMA1
32
Software
Runtime
FEKANDU6
Status
Message
Network
Service
4F
Software
Runtime
FEModMan1
Status
Message
ASC Main
Temperature
Sensor
1
Tempera-
ture
FFKANDU6
Page 6-43
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal