Users Manual Part 3
Table Of Contents
- 3. System Fails Post-Installation Checks
- 4. Incorrect Navigation Data
- 5. System Will Not Connect to the Network
- 6. Connectivity of Each Ethernet Port
- SECTION 7 – MAINTENANCE AND REPAIR
- 1. Maintenance Requirements
- 2. Continued Airworthiness, FAR 25.1529
- 3. Airworthiness Limitations
- 4. General Instructions for Inspection
- 5. Electrical and Mechanical Inspection and Check
- 6. Instructions for Continued Airworthiness
- 7. Visual Inspection and Check
- 8. Scheduled Maintenance and Inspections
- 9. Unscheduled Maintenance
- 10. Repair Requirements
- APPENDIX A – ENVIRONMENTAL CHARACTERISTICS
- APPENDIX B – INFORMATION SHEETS
- 1. Aircraft Information Sheet
- 2. JetWave™ MCS-8562 Terminal AES Subsystem Components
- A. JetWave™ MCS-8562 Terminal AES OAE - FMA Installation Information Sheet
- B. JetWave™ MCS-8562 Terminal AES KANDU Installation Information Sheet
- C. JetWave™ MCS-8562 Terminal AES BUC-HPA Installation Information Sheet
- D. JetWave™ MCS-8562 Terminal AES Modman Installation Information Sheet
- E. JetWave™ MCS-8562 Terminal AES APM Installation Information Sheet
- APPENDIX C – CHECKLISTS
- APPENDIX D – CUSTOMER PORTAL
- 1. Customer Portal
- 2. APM Request Form
- A. Requester Name
- B. Requester Email
- C. Honeywell Representative Name
- D. Hon Representative Email
- E. PO Number
- F. DP/VAR/Customer Name
- G. DP/VAR/Customer Name Contact Name
- H. DP/VAR/Customer Name Contact Email
- I. Channel Partner/Integrator/STC
- J. Estimated APM Due Date
- K. Aircraft Make / Aircraft Model
- L. Aircraft Model Variant
- M. Additional Notes/Comments
- 3. APM Parameter File
- 4. Request Assistance
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Check discrete
installation and APM
configuration
parameters
Warning
DISCRETE I/O
PIN MAP
DUPLICATION
8
Configura-
tion
3System0
Status
Message
Log clearance
AES
Operational
Historical Log
21
SNMP
Engineering
5System0
Status
Message
Log clearance
AES Fault
Historical Log
22
SNMP
Engineering
5System0
Status
Message
Log clearance
AES Usage
Historical Log
23
SNMP
Engineering
5System0
Normal for lost
connection
Status
Message
Regulatory Log
Upload Failure
0
Regulatory
Log
7System0
format the drive using
EUI tool. If problem
reappears, contact
service provider
Critical FaultsReg Log Full1
Regulatory
Log
7System0
Status
Message
User Service
Enabled
0
Information
Events
8System0
Status
Message
User Service
Disabled
1
Information
Events
8System0
Status
Message
Geographic
Map Stored
2
Information
Events
8System0
Normal for first boot up
Status
Message
Geographic
Map download
failed
3
Information
Events
8System0
Status
Message
Aircraft On
Ground
4
Information
Events
8System0
Status
Message
Aircraft In Air5
Information
Events
8System0
Status
Message
AES in Network6
Information
Events
8System0
Status
Message
AES Out of
Network
7
Information
Events
8System0
Status
Message
AES Network
Operating
Parameters
8
Information
Events
8System0
Page 6-14
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal