Users Manual Part 3

Table Of Contents
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Status
Message
ASC 5 V
Current: Out-of-
spec
2CASC1KANDU6
Status
Message
ASC 5 V
Current: Out-of-
spec
2CASC1KANDU6
Status
Message
ASC 5 V
Current: Out-of-
spec
2CASC1KANDU6
Status
Message
ASC 5 V
Current: Out-of-
spec
2CASC1KANDU6
Status
Message
Power supply
out of regulation
0
Power
Supply
2KANDU6
Status
Message
Power supply
out of regulation
0
Power
Supply
2KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
EMIFA
Unresponsive
0
ASC BITE
EMIFA
11KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
EMIFA
Incorrect Data
1
ASC BITE
EMIFA
11KANDU6
Status
Message
EMIFA Ok2
ASC BITE
EMIFA
11KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
EEPROM
Unresponsive
3
ASC BITE
EEPROM
11KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
EEPROM
Incorrect Data
4
ASC BITE
EEPROM
11KANDU6
Status
Message
EEPROM Ok5
ASC BITE
EEPROM
11KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
ARINC 429 IRS
POST
UNRESPONSIVE
0
ASC BITE
A429 IRS
12KANDU6
If problem persist
across power cycle,
replace the KANDU
Note: this can be a
false positve
Critical Faults
ARINC 429 IRS
INCORRECT
DATA
1
ASC BITE
A429 IRS
12KANDU6
Page 6-37
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal