Users Manual Part 3

Table Of Contents
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
This could appear in
normal power off
event. Note: this can
show up at power up
prior to BLv7
Critical Faults
Heartbeat
failure
0
Software
Runtime
FEModMan1
Look for the
acompanied failure log
and address those
Note: VLAN_IP
_mapping can be
accompanied by
regulatory log full
Critical Faults
GENERAL
Module Failure
1
Software
Runtime
FEModMan1
Status
Message
LRU mtd
partition
unlocked
5
Software
Runtime
FEModMan1
Note: this can be a
false positive prior to
BLv7
Status
Message
RSSI6
Software
Runtime
FEModMan1
Check Ground speed
Label
Status
Message
Missing KANDU
information -
Ground Speed
20
Software
Runtime
FEModMan1
Check Ground speed
Label
Status
Message
Missing KANDU
information -
Ground Speed
20
Software
Runtime
FEModMan1
Reboot the system, if
problem persists,
replace Modman
Critical Faults
Network
Service
4F
Software
Runtime
FEModMan1
Reset the sytem, if
problem persist.
Replace the unit. Note:
if the additional text
show "Tests not
completed: Rssi
Manager Post
Modman ACM Mgr
Post Rssi Down
Converter Post " it is a
signature of Modem
problem and needs to
be replaced
Status
Message
POST Time Out50
Software
Runtime
FEModMan1
Page 6-23
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal