Users Manual Part 3
Table Of Contents
- 3. System Fails Post-Installation Checks
- 4. Incorrect Navigation Data
- 5. System Will Not Connect to the Network
- 6. Connectivity of Each Ethernet Port
- SECTION 7 – MAINTENANCE AND REPAIR
- 1. Maintenance Requirements
- 2. Continued Airworthiness, FAR 25.1529
- 3. Airworthiness Limitations
- 4. General Instructions for Inspection
- 5. Electrical and Mechanical Inspection and Check
- 6. Instructions for Continued Airworthiness
- 7. Visual Inspection and Check
- 8. Scheduled Maintenance and Inspections
- 9. Unscheduled Maintenance
- 10. Repair Requirements
- APPENDIX A – ENVIRONMENTAL CHARACTERISTICS
- APPENDIX B – INFORMATION SHEETS
- 1. Aircraft Information Sheet
- 2. JetWave™ MCS-8562 Terminal AES Subsystem Components
- A. JetWave™ MCS-8562 Terminal AES OAE - FMA Installation Information Sheet
- B. JetWave™ MCS-8562 Terminal AES KANDU Installation Information Sheet
- C. JetWave™ MCS-8562 Terminal AES BUC-HPA Installation Information Sheet
- D. JetWave™ MCS-8562 Terminal AES Modman Installation Information Sheet
- E. JetWave™ MCS-8562 Terminal AES APM Installation Information Sheet
- APPENDIX C – CHECKLISTS
- APPENDIX D – CUSTOMER PORTAL
- 1. Customer Portal
- 2. APM Request Form
- A. Requester Name
- B. Requester Email
- C. Honeywell Representative Name
- D. Hon Representative Email
- E. PO Number
- F. DP/VAR/Customer Name
- G. DP/VAR/Customer Name Contact Name
- H. DP/VAR/Customer Name Contact Email
- I. Channel Partner/Integrator/STC
- J. Estimated APM Due Date
- K. Aircraft Make / Aircraft Model
- L. Aircraft Model Variant
- M. Additional Notes/Comments
- 3. APM Parameter File
- 4. Request Assistance
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Status
Message
Disconnect
Event
5
Operational
Information
FAModMan1
Status
Message
User Bytes
Passed
6
Operational
Information
FAModMan1
Status
Message
Standard
Electronic
Information
A
Operational
Information
FAModMan1
Status
Message
Honeywell
Electronic
Information
B
Operational
Information
FAModMan1
Status
Message
Subassemby
Information
C
Operational
Information
FAModMan1
Status
Message
CABLE
CALIBRATION
SUCCESS
20
Operational
Information
FAModMan1
Status
Message
IP Security
Event
0IP SecurityFBModMan1
Protect the port from
unknown traffic
Critical Faults
Segregation
Fault
1IP SecurityFBModMan1
Check the aircraft
services configuration
and restore as
appropriate. Protect
the interface
Critical Faults
Configuration
Fault
20IP SecurityFBModMan1
Status
Message
Power Cycle0ResetFCModMan1
Status
Message
Watchdog1ResetFCModMan1
Status
Message
Software
Command
2ResetFCModMan1
Status
Message
Reset Pin3ResetFCModMan1
Status
Message
SW exception4ResetFCModMan1
Dataload Modman
Software
Critical Faults
HW SW
Compatibility
1
Software
Configuration
FDModMan1
Dataload Modman
Software
Critical Faults
LRU SW
Compatibility
2
Software
Configuration
FDModMan1
Page 6-21
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal