(5) The fault log contains the details that follow:
LRU POST and BITE fault codes and texts-
- Location information, if available
- LRU Recorded Temperature, if available
- LRU Recorded Time, if available, if unavailable default time will be displayed
- LRU Antenna pointing information, if applicable
- Occurrence count.
(6) To download the fault log data for analysis and trouble shooting, press the “Download”
button. The window as shown in Figure 6-3 will come into view. Save to the computer to
open and view the fault log in csv format.
J. System Data Load Failure
(1) Make sure that the system is configured for ground operation.
(2) Make sure that the local data load enable switch is closed.
(3) Make sure that the ARINC 615A data loader is connected to the correct port:
NOTE: Port AV1 is by default the Modman Maintenance Port, but this may have been
modified by the APM configuration loaded.
K. System Reset
The JetWave™ MCS-8562 Terminal can be reset with any of the methods that follow:
GUI-
- Through the SNMP for Maintenance level
- By grounding the Modman Reset Pin (MP10C).
NOTE: The maintenance technician can attempt to cycle power to the Modman in case the
system fails to respond to the reset. If the problem persists, the respective AES sub
assembly needs to be replaced. The operator’s JetWave Customer Support can be
contacted for further support.
L. Electrical and Mechanical Inspection and Check
Periodic inspections of the mechanical and electrical interfaces of the JetWave™ MCS-8562
Terminal AES OAE assembly and LRUs to the aircraft should be completed as defined by the
governing airworthiness body (such as Transport Canada, the FAA, or the JAA) Instructions for
Continued Airworthiness for the installation.
For the general guidelines, refer to Visual Inspection and Check and Scheduled Maintenance and
Inspections sections. GUI summary page contains an intra Links Health Status that provides a
guidance on the health of the interconnection between LRUs.
Page 6-7
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal