SECTION 6 – TROUBLESHOOTING
1. Post-installation T
roubleshooting
This section supplies troubleshooting procedures for the JetWave™ MCS-8562 Terminal. Airline maintenance
engineers can troubleshoot the JetWave™ MCS-8562 Terminal on the ground, with the health status
information and Fault Details and Isolation assistance displayed on the AES GUI.
Only qualified avionics personnel who are knowledgeable in the technical and safety issues related to the
troubleshooting of aircraft communications equipment should do the troubleshooting.
2. Accessing the Maintenance Interface
A. For maintenance activities, the JetWave™ MCS-8562 Terminal can be accessed through a GUI.
B. Entry condition:
(1) JetWave™ MCS-8562 Terminal is installed and validated by installer for a system
safe-to-turn-on. Installer performs system Power On of all JetWave components.
(2) Aircraft prepared for troubleshooting
C. Monitoring equipment:
(1) It is recommended to use a laptop computer with the following minimum requirements:
(a) Intel i5 CPU
(b) 4 GB of Ram
(c) 500 MB of available hard drive space
(d) An available 10/100/1000 Ethernet interface
(e) Windows 7 or newer operating system, 64-bit.
(2) Ethernet cable for laptop connection to the JetWave™ MCS-8562 Terminal maintenance
port, typically Av1.
D. Monitoring equipment configuration:
(1) Configure monitoring laptop Ethernet adapter to match JetWave™ MCS-8562 Terminal
IP address settings. Go to Windows/Control Panel/Network and Sharing Center/Change
Adapter Settings/. Select Properties, within LAN properties select Internet protocol Version
4 (TCP/IPv4) and click button Properties. Select Use the following IP address radio button,
fill in:
(a) IP address to be 172.29.55.10
(b) Subnet mask to be 255.255.255.0
NOTE: The proper IP address and subnet may depend upon the installation’s
APM configuration file settings.
(c) Press OK and close.
E. Connecting Monitoring equipment to the JetWave™ MCS-8562 Terminal for a Normal Operation:
(1) Locate JetWave™ maintenance port. Connect Monitoring laptop via Ethernet cable to the
JetWave™ MCS-8562 Terminal.
Page 6-1
23-15-84
EFFECTIVITY
ALL
11 Nov 2020