Users Manual Part 2
Table Of Contents
- SECTION 4 – SOFTWARE CONFIGURATION
- SECTION 5 – SYSTEM COMMISSIONING
- SECTION 6 – TROUBLESHOOTING
Table 5-5. JetWave™ MCS-8562 EIRP SD Vs Skew Angle (29 ~ 30 GHz)
EIRP SD (dBW/40KHz) For GSO
only
EIRP SD (dBW/40KHz)Skew angle (degrees)
29.719.80
32.021.25
32.325.710
33.733.415
34.634.620
35.035.025
34.334.330
34.334.335
34.534.540
35.135.145
36.036.050
33.433.455
30.130.160
25.225.265
21.921.970
19.619.675
18.018.080
17.117.185
16.816.890
(2) Mission Configuration file Upload/Create/Edit/View/Purge/Download:
(a) The Mission configuration data is entered using the AES GUI Mission Configuration
page. Mission Configuration GUI page will be available only if IF Switch is installed
as indicated by the APM configuration parameter and with AES GUI access level
of Maintenance.
(b) Following operations are available with Mission Configuration files:
- Upload from external PC, an offline created Mission Configuration file, using
the UPLOAD button.
- Generate a new Mission Configuration file using the CREATE button and upon
entering the parameters press SAVE button. To revert to the previous page,
press the EXIT button.
- Edit or view an existing Mission Configuration file using the EDIT/VIEW button
Page 5-40
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal