Users Manual Part 2
Table Of Contents
- SECTION 4 – SOFTWARE CONFIGURATION
- SECTION 5 – SYSTEM COMMISSIONING
- SECTION 6 – TROUBLESHOOTING
C. Discrete Input Testing
(1) If wired, activate the Modman Reset by toggling Modman reset switch on the JetWave™
MCS-8562 Terminal AES control panel.
(2) If the Modman Reset is not wired, then reset the system from the GUI.
(3) Monitor the “status” LED on the front of the Modman, progresses from red color to steady
state green as seen during initial power-on.
(4) Check the Aircraft Tail number page and make sure that the aircraft tail number page is
updated with the aircraft Tail number.
(5) Navigate to the Discrete Link Status page and scroll down to see the ARINC 791 Discrete
input and output state of the JetWave™ MCS-8562 Terminal. Refer to Figure 5-7.
(6) For illustration, the figure that follows shows the AES discrete signal state. Use the wired
aircraft interfaces to toggle and see if the applicable discrete are asserted or de-asserted.
Page 5-19
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal