Figure 4-11. Load Operation Completed
WARNING: WAIT 12 MINUTES OF UNINTERRUPTED
POWER-ON-TIME AFTER RELEASING THE DATA LOAD
DISCRETE. THE SYSTEM FUNCTIONS AND GRAPHICAL
USER INTERFACE MAY BE USED DURING THIS TIME.
h Once all LRUs are updated, de-assert the data load discrete to
reset the system.
F. JetWave Load Procedure
(1) 615A Data Load Setup
(a) Power on the JETWAVE system
(b) Connect the data load PC to the JETWAVE system with an Ethernet connection
enabled for data loading
NOTE: Typically this connection will be the JETWAVE system AV1 port but
may be different for each aircraft type.
(c) On the data load PC, open a web browser and in the location bar enter IP address
172.29.55.1, and then press “Enter”. This will open the AES GUI as shown in
Figure 4-12.
(d) At the GUI login, enter the username “User” and click “Log in”. The password field
should be left blank.
Page 4-17
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL