Users Manual Part 2

6 Assert the data load enable discrete noting that installations may connect
this Modman input to a switch or to another aircraft subsystem.
7 Use the ARINC 615A data loader to discover the JETWAVE system data
loadable LRUs including Modman, KANDU, BUC-HPA, APM, and FMA.
a APM Data Load
(1) Choose the desired APM file for the install. Refer to
Appendix D for obtaining the file.
(2) Load the desired .luh file on the data loader.
(3) Start the data load of the APM.
(4) The progress reported by the LRU stays at 0 percent
during file transfer. The progress will jump to 10 percent
when the files are fully transferred and are being
unzipped. Expect a total load time of up to 5 minutes for
the APM.
(5) If the load fails, reboot the system by de-asserting the
data load discrete. Wait 10 minutes, then re-assert the
data loading discrete and restart the load for that unit.
You may have to restart the data loader tool to
re-establish communication with the LRU. If multiple data
load failures are experienced, refer to JETWAVE-23-0006
for repair instructions.
(6) Data Load Completion
Once data loading all required LRU software releases
are completed, switch the data load enable discrete to
the disabled state, this will cause a system reboot.
(b) Loading with Satcom Loader
1 Data Loading the APM LRU
a Select JETWAVE APM from the drop down menu of the main
screen. Navigate to the Utilities tab as seen in Figure 4-6, and
click Discover Direct. A window will pop up verifying that the
LRU is communicating with the JetWave Loader tool.
Acknowledge the window pop-up by clicking OK
Page 4-11
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal