Users Manual Part 2

E. Load APM configuration files
(1) The APM configuration files are install specific and should be loaded before the rest of the
installation is performed. For instruction on obtaining the files, refer to Appendix D.
NOTE: The following procedure supports any ARINC 615A data loader that supports
the ARINC 665-2 file format. If you do not have the ARINC 615 data loader
tool, the Honeywell Satcom Loader has been made available. Refer to the
Service Bulletin for instructions on setting up JetWave Loader or 615A
dataloader for JetWave MCS8562 system
(a) Generic Load Procedure
NOTE: The IP address used to connect to the JETWAVE system may differ
based on customer APM configuration. The following procedure is
applicable to the default setting.
1 Power on the JETWAVE system.
2 Connect the data load PC to the JETWAVE system with an Ethernet
connection enabled for data loading.
NOTE: Typically this connection will be the JETWAVE system AV1
port but may be different for each aircraft type.
3 On the data load PC, open a web browser and in the location bar enter
IP address 172.29.55.1, and then press Enter. This will open the AES
GUI as shown in Figure 4-4.
Page 4-7
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal