Users Manual Part 1

Table Of Contents
Figure 3-5. LAIM Assembly with FMA and BUC-HPA Placement on Aircraft (Typical Installation)
(e) On completion of the LRU interconnection and applying power to the FMA, the
FMA will stay in its current position until it is told to move by the KANDU.
6. Inspection of Waveguide
A. FMA Human Exposure to RF EM Fields
W
ARNING: THE JetWave MCS-8562 Terminal IS A SOURCE OF NON-IONIZING
RADIATION.
(1) The Minimum Safe Distance:
FMA = 66.6 feet (20.3 m).-
NOTE: The minimum safe distance for occupational/controlled exposure is determined
based on the computational method specified in FCC Office of Engineering
and Technology; Bulletin Number 65, Edition 97-01: Evaluating compliance
with FCC Guidelines for human exposure to Radio Frequency Electromagnetic
fields.
(2) The areas which the risk exists are based upon the location of the antenna. This means
personnel operating on the apron, transient personnel, and the general population in the
controlled exposure category will not be exposed to levels in excess of the limits.
Maintenance personnel working close to the tail must be protected by disabling the
transmitter before they approach that area of the aircraft.
Page 3-23
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal