Table 3-5. Discretes Table (Cont)
Mandatory / OptionalDescriptionPinDiscrete I/O
MandatoryThe front panel enable
mode discrete enables the
Modman front panel
connectors when
asserted.
- Ground = Enable Front
Panel Connector
- Open = Disable Front
Panel Connector.
Signal type: Input.
Recommended that this
discrete is hardwired to
ground or connected to a
maintenance panel switch.
Modman J1-B Pin 10FFront Panel Enable Mode
OptionalThe modem mode is
configured by the AES
system configuration data.
- Ground State Internal
indicates A791
Discrete Ground State
= Internal modem,
Open State = External
modem
- Ground State External
indicates A791
Discrete Ground State
= External modem,
Open State = Internal
modem
Modman J1-B Pin 11CExternal Modem Enable
NOTE: The following ARINC 791 discretes are not supported:
Cell Transmit Enable (Modman J1-MP11B)-
- Remote Management Enable (Modman J1-MP10A)
- Cooling System Available (Modman J1-MP11F).
3. KANDU
Refer to Figure 3-9 for outline and installation information. Refer to Figure 3-12 for the applicable interconnect
diagram.
There are no special tools, fixtures, and equipment required for the installation of the KANDU.
The customer is responsible for the bulkhead connectors.
Page 3-11
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal