Users Manual Part 1
Table Of Contents
- TITLE
- TRANSMITTAL INFORMATION
- RECORD OF REVISIONS
- RECORD OF TEMPORARY REVISIONS
- SERVICE BULLETIN LIST
- LIST OF EFFECTIVE PAGES
- TABLE OF CONTENTS
- SECTION – INTRODUCTION
- SECTION 1 – SYSTEM DESCRIPTION
- SECTION 2 – SYSTEM PRE-CONFIGURATION
- SECTION 3 – INSTALLATION
Table 3-5. Discretes Table (Cont)
Mandatory / OptionalDescriptionPinDiscrete I/O
MandatoryThe discrete shall disable
the transmission of signals
when grounded, and allow
transmission when open.
Signal type: Input
KANDU J1-DTX Control
OptionalThe discrete shall disable
the PODD interfaces when
grounded, and enable
PODD interfaces when
open.
Signal type: Input
Modman J1-MP11EPublic Services Disable
MandatoryThe discrete shall request
the AES when in normal
operation mode to ignore
Air/Ground status and
provide user service.
- Ground = Enable RF
transmission on the
ground.
- Open = Normal.
Signal type: Input
Modman J1-MP11DGround Transmit Enable
OptionalThis discrete can be used
to reset the Modman (and,
in turn the entire AES)
- Ground = Mod-
man/AES reset
- Open = Mod-
man/AES normal
operation
- Signal type: Input
Modman J1-MP10CModman Reset
Page 3-9
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal