Users Manual Part 1

Table Of Contents
Table 3-2. Modman ARINC 600 Connector (Cont)
QtyDescriptionConnector PN
1#16 pin contactsPN: 620230
5Size 16 optical contacts (not used)PN: not included
2Size 5 coax contact for RF connectionsPN: 620022
NOTE: While engineering the JetWave MCS-8562 Terminal LRU interconnections,
make sure the LRU quadrax terminations do not distort natural wire orientations.
There are geometric relationships that must be maintained between the quadrax
contact and the natural twist of the star-quad wire. Wire bend radii and clamping
conditions typical of aircraft installations should not cause deviation from NEXT
parameters of the ARINC 664 compliant Star Quad cables for Ethernet
interfaces terminating on Quadrax receptacles. Refer to the applicable
interconnection diagrams for the indicator that the connector rotation of the
wire is in a clockwise direction. Refer to Figure 3-1 for information on
Recommended Interconnect Wiring Pin Numbering.
Page 3-3
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal