Users Manual Part 1
Table Of Contents
- TITLE
- TRANSMITTAL INFORMATION
- RECORD OF REVISIONS
- RECORD OF TEMPORARY REVISIONS
- SERVICE BULLETIN LIST
- LIST OF EFFECTIVE PAGES
- TABLE OF CONTENTS
- SECTION – INTRODUCTION
- SECTION 1 – SYSTEM DESCRIPTION
- SECTION 2 – SYSTEM PRE-CONFIGURATION
- SECTION 3 – INSTALLATION
(3) Install wiring in accordance with the interconnection diagram. The cables and adapters
are available as installation kits from various suppliers.
(4) Do wiring and RF cable checks to make sure they are installed correctly and meet the
installation requirements.
(5) Apply power to the system.
(6) Install radome after completion of post installation checks.
2. JetWave™ MCS-8562 Terminal Internal LRU Installation
A. Modman
Install the Modman in a standard 4-MCU tray. The customer is responsible for providing the
mounting tray, the mating ARINC 600 connector, contacts, all the cabling for the installaton as well
as any installation measures necessary to prevent the Modman from being exposed to dripping
water.
Refer to Figure 3-6 or Figure 3-7 for outline and installation information, and Figure 3-12 for the
applicable interconnect diagram.
There are no special tools, fixtures, and equipment required for the Modman installation.
Minimum clearance for the Modman: 1.0 inch (25.4 mm) clearance from top face, 0.5 inch (12.7
mm) clearance from all the other faces not interfacing with the mounting tray.
(1) The Modman mounting kits are as follows:
The customer is responsible for providing the mounting tray. Carlisle Interconnect
Technologies supplies 4-MCU ARINC 600 kits in various configurations, contact Carlisle
at www.carlisleit.com.
(2) The Modman connectors are as follows:
Table 3-1. Mating Connector
Radiall P/NMating Connector
NSXN2B875S00ARINC 600 Connector
Table 3-2. Modman ARINC 600 Connector
QtyDescriptionConnector PN
1ARINC 600 connector shell Size 2 with insertsPN 620 601 191
Arrangement Q11, Shell Size 2:Insert A:
11Size 8 quadrax contact for Ethernet connectionsPN 620176008
Arrangement 120Q2, Shell Size 2:Insert B:
118Size 22 Socket ContactsPN: 620361
2Size 8 quadrax contact for Ethernet connectionsPN 620176008
Arrangement 12F5C2, Shell Size 2:Insert C:
4#12 pin contactsPN: 620240
Page 3-2
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal