Users Manual Part 1
Table Of Contents
- TITLE
- TRANSMITTAL INFORMATION
- RECORD OF REVISIONS
- RECORD OF TEMPORARY REVISIONS
- SERVICE BULLETIN LIST
- LIST OF EFFECTIVE PAGES
- TABLE OF CONTENTS
- SECTION – INTRODUCTION
- SECTION 1 – SYSTEM DESCRIPTION
- SECTION 2 – SYSTEM PRE-CONFIGURATION
- SECTION 3 – INSTALLATION
Table 1-5. BUC-HPA Leading Particulars (Cont)
SpecificationCharacteristic
2.08 inches (52.8 mm) maximumHeight
11.5 pounds (5.2 kg) maximum (including thermal pad)
BUC-HPA 10.75 pounds (4.9 kg) nominal
Thermal pad 0.75 pounds (0.34 kg) nominal
Weight
115 VAC, 400 HzOperating voltage
220 watts maximum at MOP 96-122 VACPower consumption
200 watts maximum at MOP 96-122 VACPower dissipation
Conductive - cooled through the baseplate with thermal pad.
BUC-HPA will mute the transmit RF signal if the hottest point on the
aircraft baseplate exceeds 185°F (85°C).
BUC-HPA will automatically un-mute once BUC-HPA cools below
167˚F (75˚C).
Cooling
-67°F (-55°C) to 185°F (85°C)Operating temperature
No scheduled maintenance requiredMaintenance
J1 - Aircraft power input
J2 - Control interface from KANDU
J3 - RF TX to OAE
J4 - IF RX from OAE
J5 - IF TX from Modman
J6 - IF RX to Modman
Interfaces
Table 1-6. FMA Leading Particulars
SpecificationCharacteristic
90002609-001Part Number
23.03 inches (585 mm) maximumLength
35.72 inches (907.3 mm), maximum reflector sweep volumeWidth
9.39 inches (238.51 mm) maximumHeight
88 pounds (39.92 kg) maximum
NOTE: The lifting fixture is 5.5 pounds (2.5 kg)
Weight
38 VDC and 24 VDC for IMU supplied by the KANDUOperating voltage
-67°F (-55°C) to 158°F (70°C)Operating temperature
160 W @ steady statePower dissipation
Natural convection and radiation onlyCooling
Page 1-4
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal