Table 1-3. APM Leading Particulars (Cont)
SpecificationCharacteristic
Power supplied by ModmanPower consumption
0.3 watts maximumPower dissipation
No forced-air cooling requiredCooling
5°F (-15°C) to 158°F (70°C)Operating temperature
No scheduled maintenance requiredMaintenance
J1 - ModmanInterface
Table 1-4. KANDU Leading Particulars
SpecificationCharacteristic
90404518Part Number
11.020 inches (279.91 mm) maximumLength
9.075 inches (230.50 mm) maximumWidth
4.760 inches (120.90 mm) maximumHeight
8.8 pounds (4.0 kg) maximumWeight
115 VAC, 400 HzOperating voltage
200 watts maximum average power when installed with Class A
FMA
Power consumption
50 watts maximum average power when installed with Class A
FMA
Power dissipation
See 90405004 Outline and Installation Drawing for the KANDU
for cooling clearance requirement
No forced-air cooling required
Cooling
-67°F (-55°C) to 158°F (70°C)Operating temperature
No scheduled maintenance requiredMaintenance
J1 - Aircraft and Modman
J2 - Power to OAE and IMU (38.5 and 24 VDC)
J3 - BUC-HPA, OAE, and maintenance
J4 - Ethernet (quadrax)
Interfaces
Table 1-5. BUC-HPA Leading Particulars
SpecificationCharacteristic
90003227-003Part Number
16.55 inches (420.4 mm) maximumLength
9.01 inches (228.9 mm) maximumWidth
Page 1-3