User's Manual Part 6

Page 7-38
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
FMA
(04)
Unknown (00) 0x 0012 LRU menu access - factory Info events - Recording what
happened in the LRU
0x 0013 LRU menu access - engineering
0x 0014 LRU SFTP access - maintenance
Unknown (00)
0x 0015 LRU SFTP access - factory Info events - Recording what
happened in the LRU
0x 0016 LRU SFTP access - engineering
0x 0021 Log clearance LRU operational
0x 0022 Log clearance LRU fault
0x 0081 Azimuth home find fail Hardware faults and events:
- Replace the FMA.
0x 0082 Elevation home find fail
0x 0085 Ice breaker AZ
0x 0086 Ice breaker EL
0x 0087 Azimuth axis out of band
0x 0088 Elevation axis out of band
Inertial
measurement
unit (02)
0x 0001 No response Replace the FMA
Position control
unit (05)
0x 0001 DSP fault Hardware faults and events:
- Replace the FMA.
0x 0081 1.2V voltage
0x 0082 1.5V voltage
0x 0083 1.8V voltage
0x 0084 3.3V voltage
0x 0085 5V positive voltage
0x 0086 1.2V current
0x 0087 1.5V current
0x 0088 1.8V current
0x 0089 3.3V current
0x 008A 5V positive current
PSU (06) 0x 0003 PSU low power detected
0x 0004 PSU low power not detected
0x 0005 PSU LNA current event
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017