User's Manual Part 6
Page 7-73
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Aircraft
State
Input Bus
(71)
Unknown (00) 0x 0000 Inactive link Aircraft Interconnect.
Means we see no labels on the bus:
- Check wiring
- Check source
- Check KANDU and Modman.
Pitch angle label
(01)
0x 0001 Missing Expected label is not there:
- Make sure that the system
configuration expects the correct
label.
- Check aircraft system is supplying
the correct label on the bus.
If fault is critical, the system will not
work.
If fault is a warning, the label is
expected but not there, the system
will continue to operate.
0x 0002 SSM FT Expected label is in functional test:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017