With the LAIM, the radome will be installed on the Radome skirt fairing assembly. Refer to Figure
4-20.
Electrical bonding from the Jetwave™ radome lightning diverters into the airframe must be less
than 25 milliohms.
NOTE:
The segmented diverter strips on Jetwave™ radomes do not have electrical continuity
between the segments (buttons). Bonding measurements must be made at the diverter
termination points on the radome (at the radome attachment fastener).
Figure 4-20. Radome Assembly Mounted on Radome Skirt Fairing (LAIM)
A. FMA Human Exposure to RF EM Fields
WARNING: THE JETWAVE™ SYSTEM IS A SOURCE OF NON-IONIZING RADIATION.
(1) The Minimum Safe Distance:
FMA = 66.6 feet (20.3 m).
NOTE: The minimum safe distance for occupational/controlled exposure is determined
based on the computational method specified in FCC Office of Engineering and
Technology; Bulletin Number 65, Edition 97-01: Evaluating compliance with FCC
Guidelines
for human exposure to Radio Frequency Electromagnetic fields.
(2) The areas which the risk exists are based upon the location of the antenna. This means
pers
onnel operating on the apron, transient personnel, and the general population in the
controlled exposure category will not be exposed to levels in excess of the limits.
Maintenance personnel working close to the tail must be protected by disabling the
transmitter before they approach that area of the aircraft.