User's Manual Part 2
Page 4-33
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
(1) TX-IF connects from the Modman through the bulkhead J4B to KRFU J5.
(2) RX-IF connects from the Modman through the bulkhead J3B to KRFU J6.
b Make sure that the TX-IF coax cable is banded blue and RX-IF coax cable is
banded green at connector ends.
c Make sure that the over braid of the cable assembly is terminated to connectors
at both KRFU and Modman or the bulkhead interface feed through ends.
d The over braid can be terminated to connector shield/housing or directly to
housing.
4 Make sure that all cable assembly routings are firmly held with wire clamps in
accordance with the airframe specific wiring diagram and that there are no
obstructions to the free movement of tail mount antenna.
On completion of LRU interconnection and applying
power to TMA, the tail mount
antenna will move in azimuth and elevation direction and move itself to its home
position.
(h) Radome and Radome Fairing Installation with the TMA Interface Mount
Radome and fairing installation is aircr
aft specific. See aircraft specific SDIM for details.
NOTE: Before removing the Tail Mount Radome, Honeywell recommends manually
steering the TMA to a safe antenna orientation position using the JetWave™
GUI. The TMA does not power down in a specific "Park" position, as there is
insufficient time on power down to accomplish this. It instead "parks" wherever
it is when power is applied, until the system is ready to operate and the antenna
automatically starts steering towards the satellite.
(i) TMA Human Exposure to RF EM Fields
WARNING: THE JETWAVE™ SYSTEM IS A SOURCE OF NON-IONIZING
RADIATION.
1 The Minimum Safe Distance:
• TMA = 30.3 feet (9.24 m).
NOTE: The minimum safe distance for occupational/controlled exposure is
determined based on the computational method specified in FCC Office of
Engineering and Technology; Bulletin Number 65, Edition 97-01:
Evaluating compliance with FCC Guidelines for human exposure to Radio
Fre
qu
ency Electromagnetic fields.
Draft as of 31 May 2017