When installing the JetWave™ system, follow the cabling requirements listed below:
Ethernet LAN/WAN cables must meet flammability and TIA/EIA568-A CAT 5E requirements.
Carlisle IT (ECS) 422404 or NF24Q100-01 is recommended for Quadrax connections.
Twisted shielded pairs must meet ARINC 791 wiring requirements or equivalent.
Refer to Figure 4-34, thru Figure 4-37 for wire size recommendations.
Refer to Figure 4-21 for the Modman (PN 90400059-0001) outline and installation drawing.
Refer to Figure 4-22 for the Modman Variant 2 (PN 90400059-0002) outline and installation drawing.
Refer to Figure 4-23 for the APM (PN 90401592) outline and installation drawing.
Refer to Figure 4-24 for the APM (PN 90405762) outline and installation drawing.
Refer to Figure 4-25 for the KANDU (PN 90401657) outline and installation drawing.
Refer to Figure 4-26 for the KANDU Variant 2 (PN 90405004) outline and installation drawing.
Refer to Figure 4-27 for the KRFU (PN 90401573), conduction-cooled 1 (maximum operating temperature
of 185°F (85°C)), outline and installation drawing.
Refer to Figure 4-28 for the KRFU (PN 90402347), conduction-cooled 2 (maximum operating temperature
of 158°F (70°C)), outline and installation drawing.
Refer to Figure 4-29 for the KRFU (PN 90401571), forced air cooled, outline and installation drawing.
Refer to Figure 4-30 for the TMA (PN 90401428) outline and installation drawing.
Refer to Figure 4-31 for the FMA (PN 90000380ICD) outline and installation drawing.
Refer to Figure 4-32 for the Fuselage Mount Radome (PN 90401395) outline and installation drawing.
NOTE:
The Fuselage Mount Radome is offered as a standard part and varying skirts can be used to
adapt this to different airframe platforms. No Tail Mount Radome is depicted as this is airframe
platform specific.
Table 4-10. Cabling Requirements
Cable Conductor Type
Single
Point
Multiple
Point
Minimum Conductor
Coverage by Shield
Power Lines Twisted pair NA NA NA
Ethernet Data Quadrax, twisted pair - Yes 100%
RF Coaxial, waveguide - Yes 100%
A429 Twisted pair, stranded - Yes 95%
RS-422 Twisted pair, shielded - Yes 100%
Discrete Twisted pair, shielded, KANDU
Single conductor, shielded, grounds
- Yes 100%
Draft as of 31 May 2017