User's Manual Part 1
Table Of Contents
- TRANSMITTAL INFORMATION
- SECTION 1 INTRODUCTION
- SECTION 2 DESCRIPTION
- SECTION 3 SYSTEM PRE-CONFIGURATION
- SECTION 4 INSTALLATION
Page 4-19
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
C. Advisories
The JetWave™ FMA and the KRFU subsystems include components that radiate RF and
microwave emission
s in the band between 29.0 and 30.0 GHz.
All service technicians and operators must be informed of the potential hazards of RF and
microwave radiation. When installing and servicing equipment, exercise the safety precautions that
follow.
WARNING: THIS EQUIPMENT RADIATES HIGH
FREQUENCY
RADIATION AND POSES A
RADIATION HAZARD. CONSIDERING THE WORST CASE CONDITION OF 100
PERCENT REFLECTION FOR THE FUSELAGE MOUNT ANTENNA, HONEYWELL
DEEMS IT NECESSARY TO ASSURE OEM FUSELAGE ATTENUATION EXCEEDS
21.03 DB FOR FUSELAGE MOUNTED ANTENNAS SYSTEM INSTALLATION. THIS IS
THE MINIMUM ATTENUATION REQUIRED FROM THE AIRCRAFT FUSELAGE TO
ATTENUATE THE KA-BAND RADIATION TO MEET A SAFE HUMAN EXPOSURE OF 1
MW/CM
2
INSIDE THE AIRCRAFT.
WARNING: SERVICE TECHNICIANS AND OPERATORS MUST EXERCISE CARE TO KEEP
CLEAR OF THE
ANTENNA’S BEAM WHILE PERFORMING OPERATIONAL TESTS OR
INSTALLATION VERIFICATION PROCEDURES. DO NOT APPROACH WITHIN 66.6
FEET (20.3 METERS) OF THE FUSELAGE MOUNTED ANTEN
NA ASSEMBLY DURING
RADIO FREQUENCY TRANSMISSION.
WARNING: DURING ANTENNA OPERATION (TRANSMISSION), MAKE SURE THA
T MINIMIZE
THE EXPOSURE OF ALL PERSONNEL TO ANY REFLECTED, SCATTERED, OR
DIRECT BEAMS.
WARNING: SERVICE TECHNICIANS MUST OBEY STANDARD SAFETY PRECAUTIONS, SUCH
AS WEARING SAFETY GLASSES
, TO PREVENT PERSONAL INJURY WHILE
INSTALLING OR PERFORMING SERVICE ON THIS UNIT.
CAUTION: THE FUSELAGE MOUNT OAE ASSEMBLY IS ELECTROSTATIC-SENSITIVE.
STANDARD ELECTROSTATIC-SENSITIVE HANDLING PROCEDURES MUST BE
OBSERVED.
D. Unpacking and Inspection
This section describes how to make sure that the eq
uipment is in
good condition after shipping. To
unpack and inspect the equipment do as follows:
(1) Unpack the equipment components from the shipping container.
(2) Make sure that all components of the fuselage mount OA
E subsystem as indicated on the
parts list/bill of materials are included.
(3) Visually examine the units for any shipping damage.
NOTE: Refer to Section 4.10 Inspection of Waveguide.
E. FMA Installation Kits
FMA installation kits are available in ARINC 791
Style configur
ations and non ARINC 791 style
configurations. See Table 4-6 and Table 4-7 for details on available installation kits for each
configuration.
Draft as of 31 May 2017