User's Manual Part 1

Table Of Contents
Page 4-6
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Local Data Load ModMan J1-MP10B The discrete shall
request the ModMan to
change mode in the
following manner:
Open to ground
transition: Request
for data load mode
to be entered
Ground to open
ground transition:
Request for reset of
system (if in data
load mode)
Signal type: Input
Mandatory
TX Control KANDU J1-D The discrete shall
disable the transmission
of signals when
grounded, and allow
transmission when
open.
Signal type: Input
Mandatory
Public Services Disable ModMan J1-MP11E The discrete shall
disable the PODD
interfaces when
grounded, and enable
PODD interfaces when
open.
Signal type: Input
Optional
Ground Transmit Enable ModMan J1-MP11D The discrete shall
request the AES when in
normal operation mode
to ignore Air/Ground
status and provide user
service.
Ground = Enable RF
transmission on the
ground.
Open = Normal.
Signal type: Input
Mandatory
Table 4-3. Discretes Table (Continued)
Discrete I/O Pin Description Mandatory / Optional
Draft as of 31 May 2017