SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Data link available (Modman MP13F) open/ ground output connected to a lamp.
(2) Discrete Inputs:
Local data load enable (Modman MP10B) connected to a normally open switch with a
GND to
enable
Ground transmit enable (Modman MP11D) connected to a norma
lly open switch with a
GND to enable
Public service disable (Modman MP11E) connected to a normally open switch with a
GND to
enable
Modman reset (Modman MP10C) connected to a normally open switch with a GND to
enable
Tx mute (KANDU J1D) connected to a normally open switch with a GND to enable.
Front Panel Enable Mode (Modman MP10F) conn
ected to a n
ormally open switch with a
GND to enable
Discrete Signal Ground (Modman MP12F), to be used as the ground reference for the
other Modm
an discrete inputs
Discrete Signal Ground (KANDU J1-B), to be used as
the ground reference for the
KANDU discrete inputs
(3) Ethernet Port:
AV1 (Modman TP BB1 thru 4) connected to a RJ45 Ethernet connector
NOTE: The AV1 is the default data loading port, any other Ethernet ports can be selected as
long as the APM configuration file is configured to allow that port to data load.
For LRU pin details, refer to the applicable system interconnect diagram, Figure 4-34 thru
Figur
e 4-37.
Refer to Table 4-3 for a list of I/O discretes.
Table 4-3. Discretes Table
Discrete I/O Pin Description Mandatory / Optional
Weight-on-Wheels
(WOW)
ModMan J1-MP11A Use and sense of the
Weight on Wheels input
is to determine
Air/Ground Status, as
configured by the AES
system configuration
data.
Signal type: Input
Optional
Draft as of 31 May 2017