User's Manual Part 1

Table Of Contents
Page 4-2
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
(2) Install the OAE and JetWave™ components in accordance with the installation drawings
provided.
(3) Install wiring in accordance with the interconnectio
n diagram. The cables and adapters are
available as installation kits from various suppliers.
(4) Do wiring and RF cable checks to make sure they are insta
lled correctly and meet the
installation requirements.
(5) Apply power to the system.
(6) Install radome after completion of post
installation checks.
4.2 JetWave™ System Internal LRU Installation
A. Modman
Install the Modman in a standard 4-MCU tray. The
customer is responsible for providing the
mounting tray, the mating ARINC 600 connector, contacts, as well as all the cabling for the
installaton.
Refer to Figure 4-22 for outline and installation information, and Figure 4-34 thru Figure 4-37 for
the applicable interconnect diagram.
There are no special tools, fixtures, and equipment required for the Modman installation.
Minimum clearance for the Modman: 1.0 inch (25.4 mm) clearance from top face, 0.5 inch (12.7
mm) clearance from all the other faces not interfacing with the mounting tray.
(1) The Modman mounting kits are as follows:
The customer is responsible for providing the mounting tray. Carlisle Interconnect
Technologies s
upplies 4-MCU ARINC 600 kits in various configurations, contact Carlisle at
www.carlisleit.com.
(2) The Modman connectors are as follows:
Table 4-1 provides the connector part numbers for the Modman rear connector. The mating
connector
(Radiall PN NSXN2B875S00) is supplied by the customer.
Table 4-1. ARINC 600 Connectors
Connector PN Description Qty
Radiall PN 620 601 191 ARINC 600 connector shell Size 2 with inserts 1
Insert A:
Radiall PN 620075050
Arrangement Q11, Shell Size 2:
Size 8 quadrax contact for Ethernet connections 11
Insert B:
PN: D38999/26FH35PN
D38999/26FD35PN
Radiall PN 620075050
Arrangement 120Q2, Shell Size 2:
#22 contacts
Size 8 quadrax contact for Ethernet connections
118
2