User's Manual Part 1

Table Of Contents
Page 3-3
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
B. Regulatory Log Configuration Parameters
The regulatory log configuration parameters file (APM file -
reglog.cfg) contains details of the
remote server to use to transfer the regulatory log data.
C. Aircraft Service Configuration
There are a number of functions that an Ethernet port can support namely, data traffic, data loading,
GUI, AES logs extraction (maintenance function) and status/control (through the SNMP). The
terminal can be configured to indicate whether an Ethernet port supports traffic, data loading,
SNMP etc, such as AG1 SNMP, and data loading, EG1 traffic, using the aircraft service
configuration file.
Once the items have been loaded into the APM the Modman reads the APM once at power-on and passes
the appropriate data to the relevant LRU or uses the information locally.
The following airframe specific information is required for creating the JetWave™ configuration files:
Applicable ARINC 429 Label Definition sets from Aircraft IRS/IRU and GNSS
Discrete input availability and its polarity
User Ethernet Ports which are to be configured and the type of services to be enabled (such as
Data Load, SNMP, GUI and OTA access).
Aircraft blockage data.
Refer to APPENDIX D on Page D-1 for more details.