User's Manual Part 1
Table Of Contents
- TRANSMITTAL INFORMATION
- SECTION 1 INTRODUCTION
- SECTION 2 DESCRIPTION
- SECTION 3 SYSTEM PRE-CONFIGURATION
- SECTION 4 INSTALLATION
Page 2-6
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Conduction-cooled 2 configuration:
Length 16.55 inches (420.4 mm) maximum
Width 9.01 inches (228.8. mm) maximum
Height 2.08 inches (52.8 mm) maximum
Weight 11.30 pounds (5.1 kg) maximum
Operating voltage 115 VAC, 400 Hz
Power consumption 300 watts maximum at transmit amplifier saturation.
220 watts maximum at maximum nominal system transmit power.
185 watts typical at maximum nominal system transmit power when
base plate is at 77°F (25°C).
210 watts typical at maximum nominal system transmit power when
KRFU base plate is at 158°F (70°C).
Power dissipation 260 watts maximum at transmit amplifier saturation.
200 watts maximum at maximum nominal system transmit power.
167 watts typical at maximum nominal system transmit power when
base plate is at 77°F (25°C).
192 watts typical at maximum nominal system transmit power when
KRFU base plate is at 158°F (70°C).
Cooling Conductive - cooled through the baseplate with thermal pad.
Operating temperature -67°F (-55°C) to 158°F (70°C).
KRFU will mute the transmit RF signal if the hottest point on KRFU
baseplate exceeds 158°F (70°C).
Operating temperature -67°F (-55°C) to 158°F (70°C)
Maintenance No scheduled maintenance required
Interfaces J1 - Aircraft power input
J2 - Control interface from KANDU
J3 - RF TX to OAE
J4 - RF RX from OAE
J5 - IF TX from Modman
J6 - IF RX to Modman
Forced air configuration:
Length 18.05 inches (458.5 mm) maximum
Width 9.01 inches (228.8 mm) maximum
Height 3.230 inches (82.04 mm) maximum
Weight 14.6 pounds (6.6 kg) maximum
Operating voltage 115 VAC, 400 Hz
Power consumption 300 watts maximum at transmit amplifier saturation.
220 watts maximum at maximum nominal system transmit power.
185 watts typical at maximum nominal system transmit power.
Table 2-7. KRFU Leading Particulars (Continued)
Characteristic Specification
Draft as of 31 May 2017