User Manual Part 3
Page 3-40
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
(a) Remove the unit
(b) Secure cables and wiring
(c) Collar applicable switches and circuit breakers
(d) Placard the JetWave™ AES LRU and associated items as “inoperative” in accordance
with the aircraft maintenance manual
(e) Before flight, do as follows:
1
Record the removal of the unit in the log book
2
Revise the equipment list. Refer to section 91.213 of the FAR or the aircraft’s
minimum equipment list.
3
Revise the weight and balance data as applicable.
(3) JetWave™ AES system LRUs are not field-repairable. Return the faulty LRUs or sub
assembly to the Honeywell authorized facility for repair.
(4) Install repaired LRUs on the aircraft in accordance with the installation instructions supplied
in this manual.
(5) Make sure that all repaired units operate correctly before you approve them for return to
service, with the operational verification tests and procedures provided in this SDIM.
Approval for return to service must be entered in the logbook as required by section 43.9 of
the FAR.
(6) Enter the approval for return to service in the appropriate logbook as required by FAR Section
43.9.
(7) Add the scheduled maintenance tasks to the aircraft operator’s appropriate aircraft
maintenance program as follows:
(a) Recommended periodic scheduled servicing tasks: None required.
(b) Recommended periodic inspections:
• Scheduled maintenance inspections supplied in Table 3-12 and in accordance the
aircraft’s inspection and maintenance schedule.
(c) Recommended periodic scheduled preventative maintenance tests (to determine
system condition and/or latent failures): None required.
C. Visual Inspection and Check
Do the procedures that follow to examine the JetWave™ AES OAE assembly and LRUs after
installation of the unit onto the aircraft. Follow all approved safety standards and practices during
the inspection.
CAUTION:
FAILURE TO DISCONNECT CIRCUIT BREAKERS CAN LEAD TO INJURY TO THE
OPERATOR AND DAMAGE TO THE EQUIPMENT.
(1) Disconnect all circuit breakers to the JetWave™ AES OAE assembly, LRUs and associated
systems.