D. System Dataload Failure
(1) Make sure that the system is configured for ground operation.
(2) Make sure that the local data load enable switch is closed.
(3) Make sure that the 615A data loader is connected to the correct port:
NOTE:
AV1 by default, but this may have been modified by the configuration loaded on the
APM.
(4) Make sure you are trying to load a valid set of files into the correct LRU.
11. Network Monitoring
The JetWave™ system supplies network performance data to SNMP applications. The available MIB
objects and traps can be found in APPENDIX B on page B-1.
12. System Reset
The JetWave™ system can be reset with any of the methods that follow:
Through the Web GUI
Through the SNMP
By closure of the Modman reset pin (MP10C) to ground.
NOTE:
The maintenance technician can attempt to cycle power to the Modman in case the system fails
to respond to the reset. If the problem persists, the respective AES sub assembly needs to be
replaced. Honeywell Field Support Engineers can be contacted for further support.
A. Electrical and Mechanical Inspection and Check
Periodic inspections of the mechanical and electrical interfaces of the JetWave™ AES OAE
assembly and LRUs to the aircraft should be completed as defined by the governing airworthiness
body (such as Transport Canada, the FAA, or the JAA) Instructions for Continued Airworthiness for
the installation.
For the general guidelines, refer to Visual Inspection and Check and Scheduled Maintenance and
Inspections sections.
B. Instructions for Continued Airworthiness
This section supplies the special instructions and maintenance requirements for continued
airworthiness of the JetWave™ AES subsystems.
(1) JetWave™ AES OAE assembly and LRUs are considered on-condition units. No additional
or routine maintenance is required for the on-condition JetWave™ AES OAE assembly and
LRUs.
(2) If a JetWave™ AES OAE assembly or an LRU is inoperative, do as follows: