User Manual Part 3

Page 3-33
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Only qualified avionics personnel who are knowledgeable in the technical and safety issues related
to the troubleshooting of aircraft communications equipment should do the troubleshooting
procedures supplied in this manual.
NOTE:
If any of the KANDU unmonitored voltage rails are not working the troubleshooting output of the
JetWave™ system would not identify the problem directly.
A. Accessing the Maintenance Interface
(1) For maintenance activities, the JetWave™ system can be accessed through a GUI.
(2) The GUI service is supported on AV1 and AG1 10/100 Base T Ethernet interface.
NOTE:
Once the configuration file is loaded, the ports where the GUI is available on can be
different.
(3) The Modman static IP assigned is 172.29.55.1 and the port number for the AES GUI service
is port 80.
NOTE:
This port is configured by the AES configuration user port services support
information.
(4) On any of the Internet browsers (Internet Explorer 8 compatible), open the link "index.html".
(5) Login page will be shown as the root page, for you to enter the user name and password.
Refer to Figure 3-18 for the screen-shot of the login page.
Figure 3-18. AES GUI Login Page
(6) Use the applicable login account with well defined password in the login page for accessing
the interface level required. The login for the maintenance interface and user interface is as
follows:
Access maintenance interface with Username: "Maintenance" and Password:
"Earthbound".