User Manual Part 3
Page 3-29
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
• User Port IP filter 1 thru 150.
Once the items have been loaded into the APM the Modman reads the APM once at power-on and
passes the appropriate data to the relevant LRU or uses the information locally.
(1) If the Ethernet port is not active, do as follows:
(a) Check the APM settings, as follows:
1
Make sure that the port is enabled.
2
Check system errors.
3
Check for system reporting No layer 1 or No traffic faults.
(b) Is the device connecting to it operating correctly? If so, check the wiring.
(2) It there is poor performance on one port only, do as follows:
(a) Check for port reporting high packet loss. If so, check wiring and verify that there is
traffic.
(3) If not supplying access to the correct services, do as follows:
(a) Make sure the APM is configured for the correct services.
(b) Make sure the APM is configured to access the correct VLANs.
(c) Check with the service provider to make sure that the VLANs have been correctly
configured for the terminal.
9. Maintenance and Repair
A. Maintenance Requirements
(1) The maintenance-free design of the JetWave™ AES system does not require field
maintenance to maintain airworthiness.
(2) Maintenance for the JetWave™ AES system is limited to replacement of LRUs on verified
failure.
(3) Field lubrication or other maintenance procedures are not required for fuselage mount
antenna assembly / tail mount antenna assembly where there are moving mechanical parts.
(4) If functional problems occur, the BITE can identify the faulty JetWave™ AES LRU and the
Modman collates this BIT information which can be accessed through the GUI provided.
Refer to theRefer to BITE Philosophy on page 3-41 of this document for information on how
to access the BIT data.
If replacement of the unit is deemed necessary, in consultation with Honeywell product support, It is
strongly recommended that all repairs be performed only at the Honeywell authorized facility.
B. Continued Airworthiness, FAR 25.1529
The sections that follow supply instructions for continued airworthiness for the JetWave™ AES
system. The sections that follow are supplied in response to Federal Aviation Regulation 25.1529,
Instructions for Continued Airworthiness.