When calibration is completed successfully, the ACM proceeds to its configured mode of operation as if
it had been restarted. When commissioning is not completed successfully, either due to an error condition
or a user cancellation, the ACM enters an inactive state.
One Touch Commissioning (OTC) is available on the AES Menu Access System.
7. Post Installation System Checkout Procedures
A. General Overview
This section supplies the information required to determine the operational readiness of the
JetWave™ system, made up of the Modman, APM, KRFU, KANDU, and OAE FMA or OAE TMA.
The installed LRUs require operational and diagnostic testing for one of the reasons listed below:
Operational verification tests that verify the operational readiness of the unit after installation on
an aircraft.
Fault verification and diagnostics to verify that a fault exists and produce system reports for
trouble shooting purposes
Operational verification of repairs that verify the operational readiness of units that have been
repaired before re-installation on an aircraft.
Only qualified technical personnel, familiar with avionics systems, should perform the test
procedures provided in this document. Before performing any test or fault isolation procedures,
read the safety advisories.
B. System Power Supply
The JetWave™ system LRUs are shipped with the operational software preloaded.
Make sure that the JetWave™ LRUs are wired and all the receptacles are connected in accordance
with applicable interconnection diagram.
Power up the JetWave™ LRUs, close applicable aircraft circuit breakers to supply power. After 5
minutes, check the Modman front panel for the Modman status.
There are two LEDs on the front panel of Modman. One is for the power and the second one is for
status. Use Table 3-11 to identify the current operating mode of Modman with the power LED
indicating powered up status.
Table 3-11. Modman LED Status Indications
Status LED Mode
Off No electrical power / electrical power is
supplied but prior to boot.
Flash green at a minimum
of 10 seconds
Modman initialization
On - green Modman in normal operation
On - red Modman in Fault Mode