User Manual Part 3
Page 3-8
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
This section contains the instructions for data loading of JetWave™ software to any of the
JetWave™ LRUs through the ARINC 600 AV1 (Maintenance Port) Ethernet interface of Modman.
Data loading of JetWave™ system can be performed while:
• JetWave™ system is in normal operation
• During system initialization
• When in critical fault mode.
The maintenance operator is responsible for determining which loads are presented to the
JetWave™ AES system through Modman for data load. JetWave™ AES system in turn will
determine the files required to meet the data load request.
The JetWave™ AES system data loading of all LRUs including uploading of the AES configuration
data can be performed through Modman. For data load purpose, Modman acts as a gateway to
JetWave™ LRUs and LRUs themselves do the data load. It is not recommended to attempt field
data load of JetWave™ LRUs directly other than through Modman.
The system configuration file is stored in nonvolatile memory in the APM and does not lose its
contents due to the loss of APM power.
On transfer of the loaded software, the Modman makes sure that the software presented by the data
loader has been loaded correctly before responding that the load is complete and will report part
numbers of the loaded software.
For illustration purpose, snap shots of AIT make F-SIM-LDR ARINC 615A data loader simulator are
included as part of this document.
(1) Parts Needed:
• Object Media CD
• ARINC 615A compliant data loading utility. The JetWave™ AES system software is
loaded through the Modman.
The JetWave™ AES loadable software part, part number varies for each release.
(2) System Software/Database Updates
Under normal circumstances, time required to carry out data load operation of all JetWave™
AES LRUs will not exceed 45 minutes for a fuselage mount systems and 60 minutes for a tail
mount system.
The data sets as shown in Table 3-2 can be transferred through the data load port in Modman
:
Table 3-2. Data Sets
LRU Data Set Transfer Process
Modman JetWave™ Modman LRU Operational
file
Upload only
APM APM configuration file Upload only, through the Modman