User Manual Part 3
Page D-11
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
B. Modman (Cont) Electrical
bonding
Bonding, refer to page 2-5
Electrical wiring Electrically wire and interconnect in
accordance with Figure 2-24 and
Figure 2-34, Figure 2-35, or Figure 2-36.
Electrical RF
coaxial
Equalizer in the TX path
TX path loss, refer to Table 2-2. Modman
Cable Loss Values
Attenuator in the RX path
RX path loss, refer to Table 2-2. Modman
Cable Loss Values
C. APM Physical Examine for physical damage.
Environmental conditions, refer to
Figure 2-25
Mounting Can be installed in any orientation. Refer
to Figure 2-25.
Use 0.164-32 UNC-2A corrosion
resistant mounting fasteners.
Do not exceed 25 in-lb (2.8 Nm) when
you torque the screws.
Electrical
bonding
Electrically bond in accordance with
page 2-6.
Electrical wiring Electrically wire and interconnect in
accordance with Figure 2-25 and
Figure 2-34, Figure 2-35, or Figure 2-36.
Electrical wiring
- APM to
Modman
Connect the APM to the Modman with
two twisted shielded 24 AWG pairs with
Teflon insulation or aerospace grade
shielded CAT5/CAT5e cable, maximum
length 9.8 feet (3 m).
Section Parameter Item NA √ Value