User Manual Part 3

Page D-7
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
B. Modman (Cont) Clearance Minimum 1 inch (25.4 mm) from top
surface and 0.5 inch (12.7 mm) from all
other surfaces
Electrical
connector
ARINC 600 mating connector and pins,
refer to Table 2-1. ARINC 600
Connectors
ARINC 600 polarized pins
Electrical
bonding
Bonding, refer to page 2-5
Electrical wiring Electrically wire and interconnect in
accordance with Figure 2-24 and
Figure 2-34, Figure 2-35, or Figure 2-36.
Electrical RF
coaxial
Equalizer in the TX path
TX path loss, refer to Table 2-2. Modman
Cable Loss Values
Attenuator in the RX path
RX path loss, refer to Table 2-2. Modman
Cable Loss Values
C. APM Physical Examine for physical damage.
Environmental conditions, refer to
Figure 2-25
Mounting Can be installed in any orientation. Refer
to Figure 2-25.
Use 0.164-32 UNC-2A corrosion
resistant mounting fasteners.
Do not exceed 25 in-lb (2.8 Nm) when
you torque the screws.
Electrical
bonding
Electrically bond in accordance with
page 2-6.
Electrical wiring Electrically wire and interconnect in
accordance with Figure 2-25 and
Figure 2-34, Figure 2-35, or Figure 2-36.
Section Parameter Item NA Value