User Manual Part 3

Page A-10
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
F. FMA
Section Condition Category
4 Temperature and altitude F2
NOTE: Extended operating high to 194
˚F(90˚C).
5 Temperature variation A
6 Humidity B
NOTE: At least six spot checks are required.
7 Operational shocks and crash safety B and E
8 Vibration CAT S, CURVE C
CAT R, CURVE C1
NOTE: The sinusoidal sweep rate not to exceed 0.5 octaves/minute
9 Explosive atmosphere E
10 Waterproofness Y and W
11 Fluid susceptibility - De-ice fluids only F
12 Sand and dust D
13 Fungus resistance F
14 Salt fog S
15 Magnetic effect B
16 Power input X - not required
17 Voltage spike X - not required
18 Audio frequency conducted susceptibility X - not required
19 Induced signal susceptibility ZC
20 Radio frequency susceptibility YQ
NOTE: Q (custom) only - SW/CW (un-modulated) signal Operational:
200V/m for 100 MHz to 12 GHz
0.1 V/m 12 GHz to 16.6 GHz
No damage:
200V/m for 12 GHz to 16.6 GHz
0.1 V/m for 16.6 GHz to 18 GHz