User Manual Part 3

Page A-7
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
20 Radio frequency susceptibility MY
NOTEL:
- 0.4 to 8 GHz: 150 V/m (Pulse repetition frequency of 1 kHz and a duty cycle of 1%, switched
on and off at a 1 Hz rate and 50% duty cycle). Pulse width is 10 μsec (1% of 1 kHz).
- 0.3 to 6 GHz: 20 V/m, (Pulse repetition frequency of 200 Hz and a duty cycle of 12.5%). Pulse
width is 625 μsec (12.5% of 200 Hz).
21 Emissions of RF energy P
NOTE:
Extension of conducted emissions limits to 200 MHz at 20 dBμA and power line limits from
30MHz to 108MHz at 20 dBμA.
Extension of radiated emissions to start at 45 dBμV/m at 150 kHz to 40 dBμV/m at 2 MHz, and
at 30 dBμV/m at 2 MHz to 25 dBμV/m at 25 MHz, and at 25 dBμV/m at 25 MHz to 26.3 dBμV/m
at 30 MHz, and at 36.3 dBμV/m at 30 MHz to 44.5 dBμV/m at 100 MHz.
22 Lightning induced transient susceptibility A3K3L3
NOTE: Extended to include pin injection waveform 5A level 2.
23 Lightning direct effects X - not required
24 Icing A
25 Electrostatic discharge A
26 Fire, flammability C - covers 14 CFR 25.853
Section Condition Category