User Manual Part 3

Page A-4
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
C. KANDU
Section Condition Category
4 Temperature and altitude D2
NOTE: Altitude test extended to 51,000 feet (15,544.8 m). Overpressure 28.9 PSI (199 kPa),
Decompression 6,000 to 55,000 (1,828.8 to 16,764.0 m).
5 Temperature variation A
6 Humidity B
7 Operational shocks and crash safety E and B
8 Vibration CAT R, CURVE E
CAT R, CURVE E1
NOTE: The sinusoidal sweep rate not to exceed 0.5 octaves/minute.
9 Explosive atmosphere E
10 Waterproofness Y and R
11 Fluid susceptibility F
NOTE: De-ice Ethylene Glycol, Hydraulic fluid phosphate ester AS1241 Type IV and V.
12 Sand and dust D
13 Fungus resistance F
14 Salt fog S
15 Magnetic effect Z
16 Power input A (WF) HZPI
NOTE: Extended low frequency operation to 320 Hz.
NOTE: Power factor – leading greater than 0.98.
17 Voltage spike A (modified to 1,000 volts)
18 Audio frequency conducted susceptibility K (WF)
NOTE: RMS amplitude of the audio signal extended to not less than 10% of the maximum normal
AC input voltage and with a power source frequency of 320 Hz in addition to 360 Hz and 800 Hz.
19 Induced signal susceptibility CW
NOTE: Extended low frequency operation to 320 Hz.
NOTE: With current and distance modified to 50 A at a distance of 0.4 inch (10 mm) for section
19.3.1.