User Manual Part 3

Page 3-69
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KANDU (06) Software
configuration (FD)
0x 0006 LRU PRI-SEC image
mismatch
- Reboot the LRU to load valid primary
image and check if fault goes away.
- If not, then a fresh data load of software
is required to load the fresh image.
Software
configuration (FD)
0x 0007 Data load Unit configuration events:
- If it is critical, something needs to be
done (reload software).
- If it is a warning, then the event was
unexpected, but will sort itself out.
- If it is info, recording what happened in
the LRU.
0x 0008 Data loader connect
0x 0009 Data loader disconnect
0x 000A Operating image list
0x 000B Secondary image
corruption warning
A fresh data load of software is required
to load the fresh image.
0x 0080 No valid alignment data Reload the configuration data with the
A615A data loading process.
Software runtime
(FE)
0x 0000 Heartbeat failure Software events:
- Critical, will cause the unit to reset.
-Warning, then the event was
unexpected, but will sort itself out.
-Info, recording what happened in the
LRU.
(For software faults there is no reason to
return box.)
0x 0001 General module failure
0x 0002 RSSI failure
0x 0003 OPENAmip failure
0x 0004 Pointing failure
0x 0005 IMU failure
0x 0020
thru
0x 007F
Other SW errors
Temperature (FF) 0x 0001 ASC main temperature
sensor
- If is a warning, it is for info only.
- If it is critical the LRU will shut down
functionally: suggest the LRU is not
correctly installed or there can be a fault
in the box generating the heat.
0x 0002 KANDU PSU remote
temperature
Modman
KANDU
Ethernet bus
(20)
Modman input
(01)
0x 0000 Ethernet no layer 1 Indicates nothing is connected:
- Check wiring between boxes.
- Check TX box is operating.
- Check RX box is operating.
0x 0001 Ethernet no traffic Is a warning that on traffic has been seen
on the bus, but layer 1 is established so a
physical link exists
0x 0002 Ethernet high packet
loss
There is an intermittent wiring problem or
hardware fault.
0x 0003 Ethernet normal System is good.
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action