User Manual Part 3
Page 3-66
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
FMA (04) Software runtime
(FE)
0x 0000 Heartbeat failure Software events:
- Critical, will cause the unit to reset.
-Warning, then the event was
unexpected, but will sort itself out.
-Info, recording what happened in the
LRU.
(For software faults there is no reason to
return box.)
0x 0001 General module failure
0x 0020 File system full
0x 0021
thru
0x 007F
Other SW errors
Temperature (FF) 0x 0001 PCU CCA - If is a warning, it is for info only.
- If it is critical the LRU will shut down
functionally: suggest the LRU is not
correctly installed or there can be a fault
in the box generating the heat.
0x 0004 R2D CCA
0x 0005 MDU CCA
0x 0006 Azimuth Motor
0x 0007 Elevation Motor
APM (05) Software
configuration (FD)
0x 0007 Data load Info events - Recording what happened
in the LRU
Operational
information (FA)
0x 000A Standard electronic
information
0x 000B Honeywell electronic
information
KANDU (06) Unknown (00) 0x 0000 Mute State
0x 0001 Primary power
interruption
0x 0011 LRU menu access -
maintenance
0x 0012 LRU menu access -
factory
0x 0013 LRU menu access -
engineering
0x 0014 LRU SFTP access -
maintenance
0x 0015 LRU SFTP access -
factory
0x 0016 LRU SFTP access -
engineering
0x 0021 Log clearance LRU
operational
0x 0022 Log clearance LRU fault
ASC (01) 0x 0020 ASC 1.2 V: Out-of-spec Hardware faults and events:
- Replace the KANDU.
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action